This Standard is about proving metered areas on the distribution network. This includes operating network fittings to isolate specified sections of networks, making sure boundary and other required valves are watertight and working, establishing inflow and outflow meters, making sure all required work has been carried out and then recommissioning once all proving work has been carried out, flushing and checking that samples have been taken. You must follow safe working and hygiene practices at all times.
This Standard is for anyone who is involved with proving metered areas on the distribution network.
Performance Criteria
You must be able to:
obtain information from reliable sources about metered areas being proved
identify sections of distribution networks which need to be isolated to establish integrity of metered areas
confirm that customers who will be affected have been informed, and that service levels will be maintained, in accordance with organisational requirements
confirm that specified network fittings are in expected locations, are accessible and are in working condition
confirm that there are no obvious sources of potential contamination on network fittings within the area you are working
access and operate relevant network fittings in the required sequence to isolate and recommission identified sections of distribution networks
deal with network fittings and equipment requiring repair and maintenance in line with organisational processes
confirm that known leaks on network fittings have been repaired prior to proving
check the water tightness of boundary valves according to organisational procedures
confirm that valve operations do not affect system pressures
confirm that those meters which provide total inflow and outflow to metered areas are accessible and in working condition
check that permanent boundary valves are marked in the correct positions on site and network plans
carry out any hygiene procedures required in line with organisational and work requirements
carry out flushing operations and discharge water in accordance with
organisational procedures
confirm that any required mains water sampling is carried, according to organisational procedures
re-commission sections of networks once all relevant proving activity has been carried out in line with work requirements
inform relevant people about progress, problems and actions taken during isolation, proving and recommissioning activities
record complete and accurate details of progress, problems and actions taken in line with organisational processes
follow safe working and hygiene practices according to relevant regulatory and statutory procedures
Knowledge and Understanding
You need to know and understand:
work requirements for isolating, proving and re-commissioning network sections
sources of information about metered areas
how to interpret network and site plans and network flow information
the effect that isolating a section of the network may have on the wider distribution system, the immediate zone, water quality and customers
service levels and organisational requirements and processes for informing customers
potential sources of contamination of network fittings
how to operate network fittings and the importance of doing it in the required sequence
how to check that isolation has been successful, the importance of doing this, and who to inform when it has been completed
the importance of checking accessibility and working conditions of boundary valves
who to report repair and maintenance details to
the importance of checking repair of network fittings
procedures for water tightness of boundary valves
reasons why valves may not be in the expected status, and the implications of changing them
the consequences of making any changes or variations to water quality and supply, with regard to organisational limits
the importance of not affecting system pressures
air venting methods to avoid bursts or water quality issues
when and how to carry out hygiene procedures
flushing procedures
water disposal procedures and the potential damage which can be caused by incorrect disposal
the need for sampling
recording requirements in relation to progress, problems and actions taken
who needs to be informed about progress, problems and actions taken and when
safety and hygiene practices and related regulatory statutory requirements relating to health and safety and street works
Prove metered areas on the distribution network
Overview
This Standard is about proving metered areas on the distribution network. This includes operating network fittings to isolate specified sections of networks, making sure boundary and other required valves are watertight and working, establishing inflow and outflow meters, making sure all required work has been carried out and then recommissioning once all proving work has been carried out, flushing and checking that samples have been taken. You must follow safe working and hygiene practices at all times.
This Standard is for anyone who is involved with proving metered areas on the distribution network.
Performance Criteria
You must be able to:
Knowledge and Understanding
You need to know and understand: